Home

How do I fix my Pelonis portable air conditioner?

Alton Alexander
By Alton AlexanderUpdated on June 4th, 2022

A Pelonis portable air conditioner is a small, self-contained air conditioning unit that can be used to cool a single room or small space. This error code indicates that the unit is not receiving enough power to operate properly. This could be due to a number of factors, such as a faulty power cord, incorrect voltage, or a tripped circuit breaker. If the unit is not receiving enough power, it will not be able to cool the space properly and the error code will be displayed.

Other common searches for this error include:

  • p1 error code air conditioner
  • pelonis portable air conditioner

1. Check the air filter and clean it if necessary

  1. Open the front cover of the air conditioner.
  2. Locate the filter and take it out.
  3. Inspect the filter for damage or debris. If necessary, clean it with a clean cloth or vacuum cleaner.
  4. Replace the filter if necessary.
  5. Close the front cover of the air conditioner.

2. Check the compressor coils and clean them if necessary

  1. Turn off the power to the compressor by unplugging the power cord.
  2. Open the cover on the compressor.
  3. Use a Phillips head screwdriver to remove the screws that secure the cover to the compressor.
  4. Lift off the cover.
  5. On the side of the compressor, locate the coils. They are usually on the top or bottom of the compressor.
  6. Clean the coils if necessary. Use a vacuum cleaner to remove dirt, dust, and other debris.
  7. Replace the cover and screws, and restore the power to the compressor.

3. Make sure the room where the air conditioner is located is well-ventilated

  1. Open all windows in the room to allow fresh air in.
  2. Turn on all fans in the room to help circulate the air.
  3. Check the APC filter and replace it if necessary.
  4. Check the condition of the coils and the fan motor.
  5. Check the filter on the air conditioner and clean it if necessary.
  6. Check the condition of the ducts and the seals around them.
  7. Check the condition of the wires and the electrical outlet.

4. Check the cooling fins and straighten them if necessary

  1. Open the front cover of the pelonis portable air conditioner.
  2. Look for the cooling fins and straighten them if necessary.
  3. Reattach the front cover of the air conditioner.

5. Check the evaporator coils and clean them if necessary

  1. Open the front cover of the evaporator coil.
  2. Look for debris or dust on the coils.
  3. If there is debris or dust on the coils, use a vacuum cleaner to clean them.
  4. If the coils need to be replaced, call a professional to do the job.

6. Check the condenser coils and clean them if necessary

  1. Check the power cord and make sure it is securely plugged into an outlet.
  2. Open the front cover of the unit.
  3. Remove the front grill by pressing down on the two tabs on either side and pulling it out.
  4. Locate the condenser coils. They are located on the bottom of the unit.
  5. Wipe the coils with a cloth or a brush.
  6. Reattach the front grill.
  7. Close the cover of the unit.
  8. Plug the power cord into an outlet and turn on the unit.
  9. If the unit does not work, check the power cord and make sure it is securely plugged into an outlet.
  10. If the unit still does not work, clean the condenser coils.

Some users might also have success with the following opitons:

  1. Inspect the air conditioner for any loose or damaged parts.
  2. Replace any damaged or missing parts.
  3. Contact a qualified technician for further assistance.